FREQUENTLY ASKED QUESTIONS
What is Far-UVC?
"Far-UVC" is the lower wavelength's part of spectrum of UVC. The term “Far-UVC” describes light with wavelength 180-230nm. Today this light emitted by Atlas Far-UVC disinfection system. This light has shorter wavelength of comnon sun light and this is why delivers extremely high energy.
How was Far-UVC discovered?
Far-UVC found in 2013, when Professor David Brenner, director of the Radiology Research Center at the Columbia University School of Public Health, discovered that shortwave length ultraviolet C band light can potentially be used as a human safe disinfection measure, and conducted experiments to prove the efficiency and safety. In 2018, Dr. Brenner published a paper on 222nm wavelength far-UVC light in Nature’s “Scientific Reports” confirming that far ultraviolet rays do not harm the skin and eyes. In 2020, Dr. Brenner published another paper in “Scientific Reports” showing that far ultraviolet rays can effectively inactivate coronaviruses and are safe for humans.
How can Far-UVC inactivate viruses while being safe for human skin and eyes?
As a matter of basic physics, 222nm far ultraviolet light is strongly absorbed by all biological material up to 1-2 micrometers. Human cells are about 40 micrometers. It cannot penetrate the top dead cell layer, stratum corneum, of our skin or the tear layer of the eyes, therefore it can’t harm living cells.
How effective is Far-UVC in inactivating viruses?
A dose of 222nm far ultraviolet as low as 1.2-1.7mJ/cm2 can inactivate 99.9% of the new airborne coronavirus. Far-UVC does not only sterilizes (makes the virus unable to reproduce itself) but also decomposes the protein membrane of the virus. This is total elimination. Atlas Far-UVC block230 70W can inactivate 99% of coronaviruses in 6 seconds and 99.9% of coronaviruses in 12seconds in 1 meter distance!!! If Atlas Far-UVC combined with photocatalytic filters then it will be able to decompose all viruses to harmless CO2 and moisture. See how UVC Air Tunnels work in our web-page pegasus-sterilizers.com/air-tunnel.html
Is 222nm far ultraviolet light (far-UVC) really safe? Any prrof?
In 2020, Kobe University scientists conducted skin irradiation experiments using hairless mice. The effects of conventional 254nm ultraviolet rays – used for decades to disinfect unoccupied spaces such as hospitals and surgical theaters – were compared with 222nm far ultraviolet rays. After up to 96 hours of irradiation exposure, the skin of the mice irradiated with 222nm showed no adverse reaction, while the skin of 254nm irradiated mice suffered burns. Irradiation experiments were also conducted on the eyes of mice (their eye structure is similar to humans), to compare the results of 254nm versus 222nm exposure. After 254nm ultraviolet irradiation, mice eyes developed keratitis, while 222nm far ultraviolet irradiation had no effect. Kobe University also tested 222nm irradiation exposure on a group of human volunteers using a very safe dose on their backs without harm.
Any proof of the effectiveness of 222nm Far-UVC?
In November 2020, the authoritative scientific journal “Nature” published an experimental paper that concluded: “Using far ultraviolet disinfection equipment can significantly reduce the virus concentration around the virus source, and the effect is comparable to N95 masks.
Who developed the ATLAS™ FarUVC block230 disinfection system?
ATLAS™ FarUVC block230 is a filtered far ultraviolet disinfection technology developed by Theodore Karavassilis and ATLAS PV COMMERCIAL MANUACTURING SINGLE MEMBER PC and uses the Far-UVC lamps of FOSHAN YUQI AVIATION OPTICES CO. The 2 companies joined forces to present you the best and safest far-UVC disinfection system combined with optic filters and photocatalytic air filters able to sterilize ALL the room and not only one part of it.
How does ATLAS™ FarUVC block230 disinfection system inactivate viruses?
ATLAS™ FarUVC block230 disinfection system emits far ultraviolet light through a special optican nanofilter which blocks wavelengths from 230-260nm which affects human cells and allows only wavelengths 200-230nm to be emitted, so deactivates the DNA or RNA molecular structure and decomposes proteinmembrane of bacteria, sporophytes, and viruses.
How does ATLAS™ FarUVC block230 Air-tunnel disinfection system inactivate viruses?
ATLAS™ FarUVC block230 Air-Tunnel disinfection system is the next Generation of far-UVC today. ATLAS brings the future today. While all far UVC devices emits far-UVC in a specific width, this means that more than 50% of the area of a room can not be sterilized. For example if we mountain the lamp on the ceiling, this meam will be expanded from the ceiling to the floor and will cover all the floor (3 meters down) but 2 meters over the floor the beam will not be so wide and will sterilize only 11% of the space because it will be focused on the 11% of the space. If it covers 3x3 meters (9 square meters) only in the floor. 2 meters over the floor will cover 1x1 meter = 1 square meter only. What block230 Air-Tunnel does, is that uses photocatalysis filters and passes air through the far-UVC lamp and sterilizes the air of the room that far-UVC beam can not sterilize!!! Far-UVC in combination with photocatalytic microfiber filters decomposes all viruses in CO2 and moisture. So the ATLAS Far-UVC block230 Air-Tunnel is the only system that sterilizes ALL the space and not a part of the space like ALL the other far-UVC do.
What are the advantages of Atlas Far-UVC block230 Air-Tunnel system technology versus traditional disinfection applications?
Atlas Far-UVC block230 Air-Tunnel system emits pure 222nm filtered far ultraviolet disinfection that effectively inactivates harmful microorganisms in the air and on surfaces. The Atlas Far-UVC block230 Air-Tunnel system can be used safely and continuously in human environments including crowded indoor spaces. Conventional ultraviolet UVC sterilization (254nm), used extensively in hospitals and surgery theatres, cannot be used in human environments because they can cause skin cancer and eye damage. Air purification disinfection equipment offers low efficiency only inactivating harmful airborne microorganisms with no effect on pathogens attached to the surface of objects and people. Chemical disinfection is labor intensive requiring continued applications, leaves chemical residues, and can be harmful to the human body. Also the add-on Air-Tunnel with photocatalysis microfiber filters sterilizes ALL the space and not a part of the space as all Far-UVCs do.
What are the product advantages of the Atlas Far-UVC block230 Air-Tunnel system disinfection system?
Harmless to humans and animals. It provides continuous high efficiency disinfection. Designed for a variety of indoor environments. It is fully automatic, easy to install, and requires no special use conditions.
Is Atlas Far-UVC block230 Air-Tunnel system patent protected?
ATLAS company has its own patent portfolio to protect product innovations. Currently, the Atlas Far-UVC block230 Air-Tunnel is patent-pending. These patents focus on the combination of the 2 technologies (far ultraviolet + photocatalysis), light distribution, and design.
Is Atlas Far-UVC block230 disinfection system safe?
The Atlas Far-UVC block230, uses a krypton chloride excimer lamp as the light source, and its central wavelength is 222nm far ultraviolet light. At the same time, it filters harmful wavelengths of ultraviolet light through a patent-pending nano-level band-pass filter, ensuring that only 200-230nm far ultraviolet light is emitted.
Is all Far-UVC safe?
No, not all Far-UVC is safe. To be safe, Far-UVC must be FILTERED to eliminate harmful wavelengths from the light source.
What is the effective coverage and disinfection rate of each Atlas Far-UVC block230 with 2x35Wlamps?
Far UVC disinfection rate is determined by the output from the source, distance, and time. Other factors including pathogen load, airflow, and air quality can affect the disinfection rates. With average or typical indoor environments, the effective coverage area of each Atlas Far-UVC block230 with 2X35W lamps is 13ft x 13ft (4m x 4m). At 1.5ft (0.5m) away from the light source, usually, the breathing layer, a 99.9% disinfection effect can be achieved in 3 seconds!!!. At 5ft (1.5m) away from the light source, usually, the active area and the surface of many objects, 99.9% disinfection can be achieved in 18 seconds. At 8ft (2.5m) away from the light source, usually, on or near the ground, 99.9% disinfection can be reached in 52 seconds!!! IT IS ONE OF THE MOST POWERFULL FILTERED FAR UVC!!!
Can Atlas Far-UVC block230 lamp achieve instantaneous disinfection?
The disinfection efficiency is based on the irradiation intensity and environmental conditions. A certain number of Atlas Far-UVC block230 disinfection fixtures can be deployed to achieve the effect of instant disinfection at the rate of 99.9%. Under normal circumstances, however, a Atlas Far-UVC block230 device can instantly reduce the virus concentration within the range of action, effectively reducing the infectivity of the virus. Even if there is a virus present, it is not infectious.
Does Atlas Far-UVC block230 meet certification standards?
The safety level is EXEMPT (internationally compliant), in line with the international safety level IEC 62471. When used as directed human UV exposure level comply with Total Threshold Value (TLV) set by American Conference of Governmental Industrial Hygienists (ACGIH®) Minimal and safe ozone emissions at 3% of standard, only 0.003mg/m3.
What organizations have certified the Atlas Far-UVC block230 lamps?
The manufacturer of lamps FOSHAN YUQI AVIATION OPTICS CO. has SGS verification and 3rd party lab test report.
Does ATLAS Far-UVC Block230 exposure tan skin?
Ultraviolet rays that cause skin tanning have a wavelength of 280nm or more, which could be very harmful. It not only causes the skin to darken, but it also damages the basal cells and increases the probability of skin cancer. ATLAS Far-UVC Block230 disinfection systems use a nano-level band-pass filter to block wavelengths beyond 230nm, therefore does not cause the skin to darken.
How is the Atlas Far-UVC block230 disinfection system installed?
Atlas Far-UVC block230 disinfection fixtures can be installed on the ceiling or wall by registered electrical workers. However, in order to reduce the risk of overexposure, the manufacturer or authorized dealer must go to the site to plan and formulate installation and use recommendations, including the minimum installation height of 2.5-5m (8.2ft to 16.4ft) from the ground, and strictly follow the ATLAS Safety Instructions.
What are the Atlas Far-UVC block230 dimensions?
The lightweight cylinder of 70W block230 device has length of 520mm (20.5in), diameter of 102mm, (4in) and a weight of 2.2kgr (4.8lb).The lightweight cylinder of 35W device has length of 420mm (16.5in), diameter of 77mm, (3.32in) and a weight of 1.0kgr (2.2lb).
What is the Atlas Far-UVC service lifecycle?
Bulb has 9,000 hours lifetime thanks to Foshan Yuqu Aviation Optics' petented technology and all the device has a lifetime of over 30,000 hours.
How to determine if the Atlas Far-UVC bulb/lamp is damaged?
When the lamp is on it emits visible blue light. If the Atlas Far-UVCfixture is on and the bulb is not emitting a blue light it is not working The bulb will be damaged if subjected to a strong external force. Damage will be visible to the naked eye. The patent-pending nano-level bandpass filter of block230(the filter of the light source) can also be damaged if subjected to strong external force. .
Can Atlas Far-UVC fixtures be used simultaneously with other UV disinfection products?
Yes, the Atlas Far-UVC can be used with other UV disinfection products. If two or more UV products are used in combination, whether they are manufactured by ATLAS or another manufacturer, please consult professional ATLAS technicians in advance to determine the total irradiance.
Once installed, how to confirm that the Atlas Far-UVC disinfection system is effective for sterilization?
A qualified professional third-party testing agency can conduct third-party acceptance. There are several ways to ensure desired efficacy: Use a qualified professional installer to survey, install and measure output. Output can be measured by certified 222nm calibrated light meters such as the ILT2400-UVC device by International Light Technologies. Light meters to have ISO17025 accreditation or equivalent accreditation. See www.intl-lighttech.com. Output can also be measured by colorimetric dosimeter products such as the Intellego Technologies products. See intellego-technologies.com.
How do you know if a Far-UVC product is safe?
For a Far-UVC product to be safe it must have a FILTER. Ensure the product manufacturer has a certified FILTERED safe output certification. UV Spectrometer is needed to read the emitted radiation wavelength VS dose. Manufacturer must has lab test report based on measurements with a Spectrometer with ISO17025 accreditation or equivalent accreditation (like ILT2400-UVC device by International Light Technologies).
Does Far-UVC guarantee disinfection?
No. Like vaccines, masks, and air filtration, Far-UVC can significantly reduce transmission but cannot eliminate the risk completely. When properly deployed, Far-UVC is one of the most effective technologies available to reduce risk. To consult us call +30-6946596490 or better email us to atlas.newtech@yahoo.com for written reply.
|